GSA.10-20-360D Pump station for electrode coating press


The pump station is used for hydraulic supply to the drive of electrode coating press
.

The station comprises adjustable axial-piston pump and nonadjustable vane pump.

Specifications:

 
Decsription
Value
Pressure range, MPa
3…20
Max pressure, MPa
21

Pumps flow, l/min
- adjustable
- nonadjustable

 
0…60
300
Electric motor nominal power, kW
37
Revolutions per minute
1,450
Nominal filtration rating, micron
32
Working fluid temperature, °Ñ
≤ 60
Working fluid
Tr-22, IGP -18
Reservoir volume, m3
1
Dimensions, mm
2,000õ2,000õ1,420
Weight, kg
1,500